The Contour Plus is the latest generation glucose meter that offers laboratory-grade accuracy:
The accuracy of the device exceeds the requirements of the new international standard ISO 15197:2013*;
The device uses “No Coding” technology. This technology enables the device to automatically encode itself every time a test strip is inserted, eliminating the need to manually enter the code, a potential source of error. No need to waste time entering the code or code chip/strip;
The device has “Second Chance” blood sample technology. This technology allows additional blood to be applied to the same test strip in the event that the first blood sample was insufficient – no need to waste a new test strip. Second Chance saves time and money
The device has a large screen and also allows you to set audible reminders to measure after meals to help with hectic work schedules to get your blood sugar measurement on time
. – It only takes a small drop of blood, 0.6 µl – enough to give an accurate result
The device measures in just 5 seconds, so you get results fast, especially important in hypoglycemia
.
Special instructions
THERE ARE CONTRAINDICATIONS.
BEFORE USE, YOU SHOULD CONSULT WITH A DOCTOR AND READ THE USER’S MANUAL.
Specifications
I. Providing accuracy comparable to laboratory:
1. The device uses multi-pulse technology, which scans a drop of blood several times and produces a more accurate result.
2. The device provides reliability in wide climatic conditions:
– operating temperature range 5°C – 45°
– humidity 10 – 93% rel. humidity
– altitude above sea level – up to 6300 m.
3. The test strip uses a modern enzyme that has virtually no interaction with drugs, which ensures accurate measurements when taking, for example, paracetamol, ascorbic acid/vitamin C
4. The glucometer performs automatic correction of measurement results with hematocrit from 0 to 70% – this allows you to obtain high accuracy over a wide range of hematocrit, which can be lowered or increased as a result of various diseases
5.Measurement principle – electrochemical
II Providing ease of use:
1. The device uses “No coding” technology. This technology allows the meter to be automatically coded each time a test strip is inserted, eliminating the need for manual code entry, a potential source of error. No need to waste time entering a code or code chip/strip; No coding required – no need to enter code manually
2. The device has “Second Chance” blood sample application technology, which allows you to additionally apply blood to the same test strip in the event that the first blood sample was not enough – no need to waste a new test strip. Second Chance technology saves time and money.
3. The device has 2 operating modes – basic (L1) and extended (L2)
Device capabilities when using Main mode (L1):
– Brief information about high and low values for 7 days. (HI-LO)
– Automatic calculation of the average for 14 days
– Memory containing the results of the last 480 measurements.
Device capabilities when using Advanced mode (L2):
– Customizable reminders for testing 2.5, 2, 1.5, 1 hours after meals
– Automatic calculation of the average for 7, 14, 30 days
– Memory containing the results of the last 480 measurements.
– Labels “Before meals” and “After meals”
– Automatic calculation of the average before and after meals for 30 days.
– Summary of highs and lows for 7 days (HI-LO)
– Personal high and low settings
4. Small blood drop size – only 0.6 µl, underfill detection function
5. Almost painless puncture with adjustable depth using the Microlet 2 piercer – A shallow puncture heals faster. This ensures minimal trauma during frequent measurements
6. Measurement time is only 5 seconds
7. Technology of “capillary sampling” of blood with a test strip – the test strip itself absorbs a small amount of blood
8. Possibility of taking blood from alternative places (palm, shoulder)
9. Possibility of using all types of blood (arterial, venous, capillary)
10. The expiration date of test strips (indicated on the packaging) does not depend on the moment the bottle with test strips is opened.
11. Big screen
12. Automatic labeling of values obtained from measurements taken with control solution – these values are also excluded from the calculation of averages
13. Port for transferring data to PC
14. Measuring range 0.6 – 33.3 mmol/l
15. Blood plasma calibration
16. Battery: two lithium batteries of 3 volts, 225 mAh (DL2032 or CR2032), designed for approximately 1000 measurements (1 year with average use)
17. Dimensions (dimensions) – 77 x 57 x 19 mm (height x width x thickness)
18. Weight 47.5 g
19. Lifetime warranty from the manufacturer
Complete set of goods
•Glucometer
•Finger piercing device Microlet 2
•5 sterile Microlet lancets
•Case
•Self-control diary
•User manual
•Quick reference guide
•Registration card
Manufacturer
Ascensia Diabetes Care Holdings AG, Switzerland
Manufacturer | Ascensia Diabetes Care, Germany |
---|---|